Page 77 - tuder

Basic HTML Version

Via E. Mattei n° 1 - 35030 Saccolongo (PD) Italia
Tel. +39-049-8016155 Fax. +39-049-8015834
www.tudertechnica.com
TUFLON SIL
Suction and delivery hose for foodstuff, pharmaceutical, cosmetic and chemicals, except for chlorine
trifluoride, chlorine and fluorine gas, oxygen difluoride, phosgene and molten alkalis (for ex. sodium).
Hose resistant to high temperatures, used as connection between pipes and fixed equipments. Designed
for the chemical industry, foodstuff, pharmaceutical and cosmetic industry, where a flexible connection is
required. The hose is produced with high quality elastomers, with excellent chemical and mechanical
properties. Phthalates free tube, tested in compliance with REACH regulation. Tested in compliance with
USP XXXII class VI, not cytotoxic according to ISO 10993 Section 5:2009.
DESCRIPTION
Tube
PFA (perfluoroalkoxy), white, phthalates free, tested in according to REACH
standards. PFA is a polymer with excellent resistance to high temperature,
mechanical stress and to oxidation. It complies with FDA 21 CFR 177.1550,
177.2600, USP XXXII class VI, ISO 10993 Sections 5,10,11:2009 and JAPAN
Ministry of Health and Welfare Notice No.370,1959 and No.201,2006
Reinforcement
synthetic plies, stainless steel wire helices, on request static wires to discharge
static electricity
Cover
smooth, white, silicone rubber. Meets FDA CFR 21 PART 177.2600,
BROCHURE 1227, BfR Recommendation XV, European Reglement
1935/2004/CE Resolution AP 2004(5), DM 21/03/1973 e seguenti, JAPAN
Ministry of Health and Welfare Notice No.370,1959 and No.201,2006. Heat,
abrasion, ageing and ozone resistant, glossy cover
Sterilization
according to 3A Sanitary Standard Class II
Marking
transfer tape TUDERTECHNICA TUFLON SIL
TECHNICAL CHARACTERISTICS
Temperature
-40°C / +150°C ( -40°F / +302°F ) The operating temperature of the hose is
directly dependent upon the specific fluid been conveyed and the length of time
the fluid is in contact with the hose
Vacuum
675 mmHg ( 26,6 inHg )
Norm
ISO 1307 for dimensional tolerances
3A Sanitary Standard Class II
Inside
diameter
Outside
diameter
Length
Working
pressure
Burst
pressure
Appr.
weight
Bending radius
[mm] [in] [mm] [in]
[mt]
[ft]
[bar]
[psi]
[bar]
[psi] [kg/mt]
[lbs/ft]
[mm]
[in]
13
0,50
24 0,94
10
32,5
10
150
40
600
0,47
0,31
45
1,77
19
0,75
30 1,18
10
32,5
10
150
40
600
0,61
0,41
70
2,76
25
1,00
36 1,42
10
32,5
10
150
40
600
0,76
0,51
90
3,54
32
1,25
43 1,69
10
32,5
8
120
32
480
0,93
0,62
120
4,72
38
1,50
50 1,97
10
32,5
7
105
28
420
1,26
0,84
140
5,51
50
1,97
62 2,44
10
32,5
7
105
28
420
1,60
1,07
180
7,09
63,5 2,50 79,5 3,13
10
32,5
6
90
24
360
2,69
1,80
320
12,60
75
2,95
91 3,58
10
32,5
5
75
20
300
3,24
2,17
380
14,96
100 3,94 117 4,61
10
32,5
4
60
16
240
5,06
3,39
580
22,84
Data refer to ambient temperature (20°C) and static conditions; we recommend a reduction of 20% working pressure for every
100°C of temperature increase. Other diameters, wall thickness and pressure only on specific request.
77